2 Inch R-Seal Rigid Panel

Boost thermal performance and cut installation times in commercial buildings across Ohio and the USA

PRODUCT OVERVIEW.

The 2 inch R-Seal Rigid panel by ENVO Solutions is a high-performance, compact, continuous insulation solution designed for metal buildings. It offers an ideal balance of thermal resistance, air and moisture control, and ease of installation for erectors, contractors, and project managers working on commercial or industrial builds in Ohio and across the USA.

This rigid panel system enhances building envelope performance while keeping costs down and schedules on track. Whether used in new builds or retrofits, it delivers excellent benefits without bulky layers or complex components.

2-inch R-Seal

PRODUCT SPECS.

WIDTH COVERAGE

3′-6/5/8″ / 3.5521′

THICKNESS

2″

*STANDARD LENGTH

8′-0″ TO 53′-0″

EXTERIOR PROFILE

PS (Polypropylene/Scrim) Bonded to rigid foam

EXTERIOR FACE

Uniformed Dimpling Pattern

INTERIOR PROFILE

PS (Polypropylene/Scrim) Bonded to rigid foam

INTERIOR FACE

Uniformed Dimpling Pattern

JOINT

Butt

FASTENING

Through fastened with support channels at finished floor and eave areas

CORE

Rigid closed cell modified Polyurethane/PUR/PIR core, structural and fire-rated components between fiber-reinforced polypropylene.

*Custom Length Panels are Available Upon Request

R-SEAL TAPE TAB DETAIL.

R-VALUE AND U-FACTOR.

R-Value

U-Factor

Thickness/Inches

Joint Style

R-15

0.064

2.0″

Butt

R-20

0.050

2.6″

Tongue & Grooved

R-22.5

0.044

3.0″

Tongue & Grooved

R-30

0.031

4.0″

Ship Lap

R-37.5

0.027

5.0″

Ship Lap

TESTING: R-SEAL.

Rigid Envelope Insulation Panel

Test/Approval

Test Method

Test Title

Results

Fire US

ASTM E84

Surface Burning Characteristics of Building Materials

Class A Listed Flame Spread FSI < 25
Smoke Developed < 450

Fire US

R-Seal E84
Actual Tested

Composite product flame-spread and smoke-developed test acual performance

Flame Spread FSI < 5
Smoke Developed < 250

Fire US

UL 1715

Full-Scale Fire Testing

PASS

Fire US

NFPA 286 Section 9
NFPA 286 Annex "C"

Full-Scale Fire Testing
IBC 803.1.2.1 / 286 Annex C

PASS

Fire Canada

CAN/ULC S102

Surface Burning Characteristics of Building Materials and Assemblies 

Class A Listed Flame Spread FSI < 25
Smoke Developed < 450

Fire Canada

CAN/ULC S138

Full-Scale Fire Testing

PASS

Structural Performance

OSHA DROP TEST STANDARD
1926.502(c)(4)(i)

Fall Protection for Walking-Working Surfaces

PASS

Air Barrier

ASTM e283 Assembly

Tested Method for Determining Rate of Air Leakage

PASS / 0.04 CFM/ft2 at 75 PA

Air Barrier

ASTM e283 Assembly Actual Tested

Tested Method for Determining Rate of Air Leakage

 0.013 CFM/ft2 at 75 PA

Air Barrier

ASTM E779 Whole Building Tested

Tested Method for Determining Rate of Air Leakage

PASS / 0.4 CFM/ft2 at 75 PA

Air Barrier

ASTM E779 Whole Building Tested

Tested Method for Determining Rate of Air Leakage

Average 0.1 CFM/ft2 at 75 PA
*Based on field testing

Water Infiltration

ASTM E331

Tested Method for Water Penetration

15 min @ 2.86 psf / PASS
2 hr @ 6.24 psf / PASS

Thermal Performance

ASTM C518-15

Tested in Accordance with ASTM C518-15 Thermal Transmission by means of the heat flow apparatus

Tested at mean temperature of 75 degrees - Thermal Resistance "R" per inch: 7.5

Tested at mean temperature of 55 degrees - Thermal Resistance "R" per inch: 7.7

Tested at mean temperature of 20 degrees - Thermal Resistance "R" per inch: 8.7

Compression Strength

ASTM D1621

Tested Method for Determining Compressive Strength

31 - psi Perpendicular

How the 2 Inch R-Seal Panel Improves Energy Efficiency

Energy loss through poorly insulated walls and leaky joints can lead to higher HVAC loads and uncomfortable interior conditions. The 2 inch R-Seal Rigid Panel helps combat this by forming a continuous, air-sealed building envelope that improves indoor climate stability.

Here’s how it supports better energy outcomes:

  • Continuous Insulation: Eliminates gaps in coverage caused by batt insulation, reducing thermal bridging across wall systems.
  • Effective Air Barrier: The PS facer and butt-joint construction help limit uncontrolled air leakage, protecting against drafts and moisture ingress.
  • Improved Temperature Control: Maintains a consistent indoor temperature throughout the year—cooler in summer, warmer in winter.
  • Lower Utility Costs: Enhancing overall performance helps reduce reliance on heating and cooling equipment.
  • Supports Code Compliance: Meets or exceeds performance requirements under local commercial energy codes.

Whether you’re aiming for wall insulation upgrades, lower operational costs, or greener building credentials, the 2 inch R-Seal panel provides a reliable and compact solution.

Where Is the 2 Inch R-Seal Panel Used?

They are ideal for commercial and light industrial applications that require fast installation and cost-efficiency, including:

  • Commercial Warehouses
  • Agricultural Storage Buildings
  • Institutional Utility Rooms
  • Metal Building Retrofits
  • Light-Use Commercial Wall Systems

This panel integrates with your building envelope systems to maintain thermal continuity and structural protection without added bulk.

Key Advantages for Builders & Owners

Why Choose ENVO Solutions for the 2 Inch R-Seal Panel?

  • Quick Installation: Lightweight construction and butt-joint profile simplify handling and fastening.
  • Code Compliance: Meets insulation and air-barrier codes across Ohio and the USA.
  • Durability: Closed-cell core and dimpled facer resist wear, weather, and impact.
  • Better ROI: Long-term energy savings at one of the lowest installed costs in its class.
  • Custom Fit: Available in extended lengths (up to 53′) to reduce seams and installation time.

Frequently Asked Questions

Q: Is the 2 inch R-Seal panel suitable for new and retrofit builds?

A: Yes, it works great in both new construction and retrofit projects.

Q: Does it help with energy code compliance?

A: Absolutely. It offers continuous insulation performance that supports compliance with U.S. and Ohio energy codes.

Q: What’s the R-value of this panel?

A: The 2 inch panel provides an R-value of 15, ideal for walls in temperate to moderately cold regions.

Q: Can I order custom lengths?

A: Custom panels of up to 53′ are available to match your project’s needs.

Upgrade Your Next Build with Reliable 2 Inch R Seal Rigid Panel

The 2 inch R-Seal Rigid Panel from ENVO Solutions delivers proven performance, energy efficiency, and installation ease backed by certifications that matter.

Are you ready to build smarter? Contact us now to get started with a custom quote or technical support.