2 Inch R-Seal Rigid Panel
Boost thermal performance and cut installation times in commercial buildings across Ohio and the USA
PRODUCT SPECS.
WIDTH COVERAGE
3′-6/5/8″ / 3.5521′
THICKNESS
2″
*STANDARD LENGTH
8′-0″ TO 53′-0″
EXTERIOR PROFILE
PS (Polypropylene/Scrim) Bonded to rigid foam
EXTERIOR FACE
Uniformed Dimpling Pattern
INTERIOR PROFILE
PS (Polypropylene/Scrim) Bonded to rigid foam
INTERIOR FACE
Uniformed Dimpling Pattern
JOINT
Butt
FASTENING
Through fastened with support channels at finished floor and eave areas
CORE
Rigid closed cell modified Polyurethane/PUR/PIR core, structural and fire-rated components between fiber-reinforced polypropylene.
*Custom Length Panels are Available Upon Request
R-SEAL TAPE TAB DETAIL.
R-VALUE AND U-FACTOR.
R-Value
U-Factor
Thickness/Inches
Joint Style
R-15
0.064
2.0″
Butt
R-20
0.050
2.6″
Tongue & Grooved
R-22.5
0.044
3.0″
Tongue & Grooved
R-30
0.031
4.0″
Ship Lap
R-37.5
0.027
5.0″
Ship Lap
Test/Approval
Test Method
Test Title
Results
Fire US
ASTM E84
Surface Burning Characteristics of Building Materials
Class A Listed Flame Spread FSI < 25
Smoke Developed < 450
Fire US
R-Seal E84
Actual Tested
Composite product flame-spread and smoke-developed test acual performance
Flame Spread FSI < 5
Smoke Developed < 250
Fire US
UL 1715
Full-Scale Fire Testing
PASS
Fire US
NFPA 286 Section 9
NFPA 286 Annex "C"
Full-Scale Fire Testing
IBC 803.1.2.1 / 286 Annex C
PASS
Fire Canada
CAN/ULC S102
Surface Burning Characteristics of Building Materials and Assemblies
Class A Listed Flame Spread FSI < 25
Smoke Developed < 450
Fire Canada
CAN/ULC S138
Full-Scale Fire Testing
PASS
Structural Performance
OSHA DROP TEST STANDARD
1926.502(c)(4)(i)
Fall Protection for Walking-Working Surfaces
PASS
Air Barrier
ASTM e283 Assembly
Tested Method for Determining Rate of Air Leakage
PASS / 0.04 CFM/ft2 at 75 PA
Air Barrier
ASTM e283 Assembly Actual Tested
Tested Method for Determining Rate of Air Leakage
0.013 CFM/ft2 at 75 PA
Air Barrier
ASTM E779 Whole Building Tested
Tested Method for Determining Rate of Air Leakage
PASS / 0.4 CFM/ft2 at 75 PA
Air Barrier
ASTM E779 Whole Building Tested
Tested Method for Determining Rate of Air Leakage
Average 0.1 CFM/ft2 at 75 PA
*Based on field testing
Water Infiltration
ASTM E331
Tested Method for Water Penetration
15 min @ 2.86 psf / PASS
2 hr @ 6.24 psf / PASS
Thermal Performance
ASTM C518-15
Tested in Accordance with ASTM C518-15 Thermal Transmission by means of the heat flow apparatus
Tested at mean temperature of 75 degrees - Thermal Resistance "R" per inch: 7.5
Tested at mean temperature of 55 degrees - Thermal Resistance "R" per inch: 7.7
Tested at mean temperature of 20 degrees - Thermal Resistance "R" per inch: 8.7
Compression Strength
ASTM D1621
Tested Method for Determining Compressive Strength
31 - psi Perpendicular
How the 2 Inch R-Seal Panel Improves Energy Efficiency
Energy loss through poorly insulated walls and leaky joints can lead to higher HVAC loads and uncomfortable interior conditions. The 2 inch R-Seal Rigid Panel helps combat this by forming a continuous, air-sealed building envelope that improves indoor climate stability.
Here’s how it supports better energy outcomes:
- Continuous Insulation: Eliminates gaps in coverage caused by batt insulation, reducing thermal bridging across wall systems.
- Effective Air Barrier: The PS facer and butt-joint construction help limit uncontrolled air leakage, protecting against drafts and moisture ingress.
- Improved Temperature Control: Maintains a consistent indoor temperature throughout the year—cooler in summer, warmer in winter.
- Lower Utility Costs: Enhancing overall performance helps reduce reliance on heating and cooling equipment.
- Supports Code Compliance: Meets or exceeds performance requirements under local commercial energy codes.
Whether you’re aiming for wall insulation upgrades, lower operational costs, or greener building credentials, the 2 inch R-Seal panel provides a reliable and compact solution.
Where Is the 2 Inch R-Seal Panel Used?
They are ideal for commercial and light industrial applications that require fast installation and cost-efficiency, including:
- Commercial Warehouses
- Agricultural Storage Buildings
- Institutional Utility Rooms
- Metal Building Retrofits
- Light-Use Commercial Wall Systems
This panel integrates with your building envelope systems to maintain thermal continuity and structural protection without added bulk.
Key Advantages for Builders & Owners
Why Choose ENVO Solutions for the 2 Inch R-Seal Panel?
- Quick Installation: Lightweight construction and butt-joint profile simplify handling and fastening.
- Code Compliance: Meets insulation and air-barrier codes across Ohio and the USA.
- Durability: Closed-cell core and dimpled facer resist wear, weather, and impact.
- Better ROI: Long-term energy savings at one of the lowest installed costs in its class.
- Custom Fit: Available in extended lengths (up to 53′) to reduce seams and installation time.
Frequently Asked Questions
Q: Is the 2 inch R-Seal panel suitable for new and retrofit builds?
A: Yes, it works great in both new construction and retrofit projects.
Q: Does it help with energy code compliance?
A: Absolutely. It offers continuous insulation performance that supports compliance with U.S. and Ohio energy codes.
Q: What’s the R-value of this panel?
A: The 2 inch panel provides an R-value of 15, ideal for walls in temperate to moderately cold regions.
Q: Can I order custom lengths?
A: Custom panels of up to 53′ are available to match your project’s needs.
Upgrade Your Next Build with Reliable 2 Inch R Seal Rigid Panel
The 2 inch R-Seal Rigid Panel from ENVO Solutions delivers proven performance, energy efficiency, and installation ease backed by certifications that matter.
Are you ready to build smarter? Contact us now to get started with a custom quote or technical support.